Relay Module LCD Delay Power Failure Cyclic Timing Electronic Components XYLJ02

₹1,199.00
+ ₹594.99 शिपिंग

Relay Module LCD Delay Power Failure Cyclic Timing Electronic Components XYLJ02

  • ब्रांड: Unbranded
द्वारा बेचा गया:

Relay Module LCD Delay Power Failure Cyclic Timing Electronic Components XYLJ02

  • ब्रांड: Unbranded

₹1,199.00

बचत करें ₹200.00 (14%)

RRP

₹1,399.00
स्टॉक में है
+ ₹594.99 शिपिंग

14-दिन की रिटर्न पॉलिसी

द्वारा बेचा गया:

₹1,199.00

बचत करें ₹200.00 (14%)

RRP

₹1,399.00
स्टॉक में है
+ ₹594.99 शिपिंग

14-दिन की रिटर्न पॉलिसी

पेमेंट के तरीके:

विवरण

Relay Module LCD Delay Power Failure Cyclic Timing Electronic Components XYLJ02

Feature:1. With liquid LCD display, the current mode is clear, very clear, simple and practical2. All the second relay module delay disconnection circuit switching delay cycle timing circuit switch 0.01 seconds (limited to small) ~ 9999 minutes (limited to large) continuous adjustable3. Has a button, the stop function (STOP button), with reversing protection, life free4. Increase sleep mode, after you can, no operation within 3 minutes, automatically turn off the liquid LCD backlight: any button wake up5. Can set different OP, CL, LOP parameters, which are independent, saved separately. You can save the parameters and do not need to be reset when you re-powerSpecification:Item Type: Relay ModuleOutput Capability: the Device Can Control or Communicate within 220V 5A or within 220V 5AQuiescent: 15mA Operating Current: 50mAHelp Life: 100,000 TimesWork Temperature: 40 to 85Size: Approx. 8.0 x 3.8 x 1.8cm / 3.1 x 1.5 x 0.7inParameter Settings1. Press Long Press the Set Button to Enter the Setup Interface;2. First Set the Working Mode, the Working Mode is Flashing, and the Working Mode is Set by Short Pressing the Up / Down Button;3. Press the Set Button, Select the Working Mode, and Enter the System Parameter Setting;4. the System Parameters Are Flickering, Varying Parameters by Short Pressing the Up / Down Key; (note: Short Press Set in P-1 ~ P-3 Mode);5. Short Press the Set Button, Enter the Corresponding Parameter Value Setting Interface, Short Press / Long Press the Up / Down Key to Change the Value Size, Modify the Interface in the Op / Cl Parameter Value, Can Switch the Decimal Point Position by Short Pressing the Stop, Change the Timing Unit ( 1s / 0.1 / 0.015 / 1min);6. All Parameter Settings Are Complete, Press the Set Button, Save the Parameter Settings and Exit the Setting InterfaceThe Main Function1. Automatic Sleep Function: in the Run Interface, by Long Press the Stop Button, Start or Turn off the Automatic Sleep Function, the Interface Will Display "on" Or"off" Has Been 3 Seconds, Automatically Exits This Interface.2. the Relay Function is Selected at the Run Interface, by Short Pressing the Stop Key, Starts or Turns the Relay Function, if the Relay Function is Turned Off, the System Flashes the Out;3. Display Content Switches in P-5 P-6 Mode, Switch the Display Content (number of Runtime / Loop) by Short Pressing the Down Key.4. There Are Seven Working Modes:P1. After the Signal is Triggered, the Relay Turns on the Op Time, then Disconnects; within the Op Time, the Signal is Triggered Again. (if the Signal Has Been Triggered, Only Once)P2. After the Signal is Triggered, the Relay Turns on the Op Time, then Disconnects; within the Op Time, the Signal is Triggered Again. (if the Signal Has Been Triggered, Only Once)P3. After the Signal is Triggered, the Relay is Turned on the Op Time. Since the Signal is Disconnected, the Signal is Triggered Again, and the Relay is Turned Off, and the Time is Stopped.(if the Signal Has Been Triggered, Only Once)P4. After the Trigger Signal, the Relay is Disconnected, the Relay Turns on the Op Time, After the Timing is Complete, Disconnect the Relay. (if the Signal Has Been Triggered, Only Once) P5. Given to the Trigger Signal, the Relay is Turned On, the Relay Disconnects the Cl Time, then Circulates the Above Action, the Loop is Again Given the Signal, the Relay is Disconnected, Stopped the Meter; the Number of Cycles (lop) Can Be SetP6. No Trigger Signals After Power-on, the Relay is Turned on the Op Time, the Relay is Disconnected by the Cl Time, Cycle the Above Action; the Number of Cycles (lop) Can Be Set;P7. Signal Hold Function if There is a Trigger Signal, the Time Clearance . (if the Signal Has Been Triggered, the Relay Has Been Turned On).Package List:1 x Relay Module
  • Fruugo ID: 365286067-791677858
  • EAN: 4841085607052

उत्पाद सुरक्षा जानकारी

कृपया नीचे दी गई इस उत्पाद से संबंधित विशिष्ट उत्पाद सुरक्षा जानकारी देखें

निम्नलिखित जानकारी इस उत्पाद को बेचने वाले स्वतंत्र तृतीय-पक्ष खुदरा विक्रेता द्वारा प्रदान की गई है।

उत्पाद सुरक्षा लेबल

CE Mark
सुरक्षा चेतावनियाँ: Check the product before use,do not let your children touch this product alone to avoid swallowing or other injuries. to ensure safe use.
सामग्री: 9% metal 91% plastic

डिलीवरी और वापसी

4 दिनों के भीतर भेजा जाएगा

  • STANDARD: ₹594.99 - के बीच वितरण सोम 23 फ़रवरी 2026–मंगल 03 मार्च 2026

चीन से शिप हो रहा है।

हम आपके द्वारा ऑर्डर किए गए उत्पादों को पूरी तरह से और आपके विनिर्देशों के अनुसार डिलीवर करने की पूरी कोशिश करते हैं। हालाँकि, यदि आपको अधूरा ऑर्डर या आपके ऑर्डर से कोई अलग आइटम प्राप्त होता है या किसी अन्य कारण से यदि आप अपने ऑर्डर से संतुष्ट नहीं हैं तो आप ऑर्डर या ऑर्डर में शामिल कोई भी उत्पाद वापस कर सकते हैं और आइटम के लिए पूर्ण रिफ़ंड प्राप्त कर सकते हैं। सम्पूर्ण वापसी पॉलिसी दिखाएँ

उत्पाद अनुपालन विवरण

कृपया नीचे दी गई इस उत्पाद से संबंधित विशिष्ट अनुपालन जानकारी देखें।

निम्नलिखित जानकारी इस उत्पाद को बेचने वाले स्वतंत्र तृतीय-पक्ष खुदरा विक्रेता द्वारा प्रदान की गई है।

निर्माता:
नीचे Fruugo पर बिक्री किए जाने वाले संबंधित उत्पाद निर्माता के संपर्क विवरण की जानकारी संबधी सूचना है।

  • Shenzhenshidongbangguojimaoyiyouxiangongsi
  • Shenzhenshidongbangguojimaoyiyouxiangongsi
  • longgangqu bantianjiedao banxuegangdadao 3012hao8707-1shi
  • Shenzhen
  • CN
  • 518000
  • kuajingpenyuyan@163.com
  • (+86)075584621615
  • https://www.dbgj.com

यूरोपीय संघ(EU) में जिम्‍मेदार व्यक्ति:
नीचे यूरोपीय संघ में जिम्मेदार व्यक्ति की संपर्क जानकारी संबंधी सूचना है। जिम्मेदार व्यक्ति यूरोपीय संघ में स्थित पदनामित आर्थिक ऑपरेटर है जो यूरोपीय संघ में बिक्री किए जाने वाले संबंधित उत्पाद संबंधी अनुपालन दायित्वों के लिए जिम्मेदार है।

  • Johnny Lin
  • EC REP SERVICES SL
  • Calle Gran Via 49, 7 Dch.,MADRID,MADRID,ES
  • Madrid
  • Spain
  • 28013
  • ecrepservice@hotmail.com
  • 34 910563102
  • https://www.OASIS-SERVICE.com