विवरण
If you just need the heating mat, please click following picture.
KT3100 Digital Thermostat Socket Incubator Temperature Controller Outlet With Timer Switch 16A 220V for Heating Pad Heat Mat
Note: Please check carefully of the picture for the EU type and FR Type, and choose the one fits you.
1. Function
The external temperature detector can detect the temperature
Set the start and stop temperature
Cycle timing, start and stop time, timer switch
It is widely used in intelligent control, such as carbon heating, aquaculture,greenhouse, home life and other places.
2.Technical parameters
Voltage 100-250VAC 50Hz
Max Load: 16A(2) 3680W.u (15A for US type )
Temperature Range: -40~120C
Accuracy: +/- 1
Timing Accuracy: MAX 10 minutes
Temperature range: -40~120C
Open circuit (or less than -40C), the first row of the screen flashes display "E1", -40~-45C, display -40C
Short circuit( or more than 120C ), the first row of the screen flashes displaty "E2", 121-129C display 120C
Lower than -10C, or higher than 100C, it will not display value behind the decimal point
Refrigeration mode, start temperature > Stop temperature
Heating mode, start temperature < stop temperature
3. Mode button
Press MODE. LCD display: temperature control mode
Timing mode F01-F04
F01
Cycling timing mode, start time(ON)/stop time(OFF) cycling timing.
F02
Count down ON mode, now Ti.s OFF, delayed(start time) ON
F03
Count down OFF mode, now Ti.s ON, delayed(stop time) OFF, countdown completion, turn off the output and exit the run
F04
Count down ON Count down OFF mode, now Ti.s OFF, delayed(start time) ON, After starting delayed ( Stop time )OFF, Stop the time to finish the countdown, close out the output and exit the operation
Temperature correction function
Long press mode button on electricity, real time temperature calibration after 2 seconds
Real time temperature correction range: -9.9~9.9C
Long press the SET for 5 seconds to automatically exit, do not save modification
Long press MODE button to exit, save the cuttent correction modification
Screen lock protection function
Press the RESET to restore the screen for one second, and restore the factory settings.
Long press MODE for 5 seconds, Then the heating or the coolling mode will flash, then it can work
Memory function after power off
Note:
It is recommended to set the difference for start and stop temperature to be greater than 1C.
If the temperature difference is too small, the temperature measurement will fluctuate at the moment of the relay switch.
If the temperature fluctuates frequently within and outside the settig range, the output will switch frequently, which will reduce heating equipment life.
Package Content
1 x Thermostat Timer Socket with temperature sensor
1 x Box
Upgrade model: KT32000 temperature controller + 24h timer
Introduction
The KT3200 temperature controller display the measured temperature, set the start and stop temperature to control the heating or cooling equipment.
It also has time function to set day and night temperature independenty.
It is widely used in intelligent control such as heating, refrigeration,brewing,reptile, aquaculture greenhouse, home life and many other places.
Specifications
Power supply: 100~250VAC 50/60Hz
Temperature control range: -40~120/-72~176
/ Switchable
Setting time: 0-24h/Daily cycle timer
Control accuracy: 1/1
Sensor: NTC10K/B3950
Output: Max 16A/230V EU/UK/FR/AU Plug
Max 15A/120V US plug
Reset function
Temperature calibration function
Memory function when power off
Working Mode: M1 temperature control mode , M2 temperature control+timer , M3 Timer can be choosen
M1 TC: Temperature control mode
Set the start and stop temperature
Heating mode: start temperature < stop temperature
Cooling mode: start temperature > stop temperature.
M2 TC+Timer: Day/Night temperature control
Set the clock, time1, time 2, TC 1, TC 2
In each 24hours, Daytime (time1~time2) run TC1 program
Night time (time2~time1) run TC2 program
M3 Timer: 2 timer period timer only
Set the clock, time1, time2
Time1~Time2: Output on
Time2~Time1: Output off
Memory function
All data except the clock will be saved after power failure.
The clock needs to be reset when power on.
If KT3200 work in M1 mode before power failure, it will automatically resume operation after power on again.
If KT3200 work in M2 or M3 mode before power failure, you will need to reset the clock at first when power on again.
Warning
1. Before you use this unit, check on the plastic shell Do not use it if there is any damaged.
2. The relay is max 16A.Please use resistance load less than 14A.Inductive load less than 2A.
3. Do not use this unit in the environment of explosive much gas, steam or dusty.
4. Do not allow children t
-
Fruugo ID:
271307976-601333361
-
EAN:
6219267885549
उत्पाद सुरक्षा जानकारी
कृपया नीचे दी गई इस उत्पाद से संबंधित विशिष्ट उत्पाद सुरक्षा जानकारी देखें
निम्नलिखित जानकारी इस उत्पाद को बेचने वाले स्वतंत्र तृतीय-पक्ष खुदरा विक्रेता द्वारा प्रदान की गई है।
उत्पाद सुरक्षा लेबल
सुरक्षा चेतावनियाँ:
WARNING! TO AVOID DANGER OF SUFFOCATION,KEEP AWAY FROM BABIES ANDCHILDREN. DO NOT USE IN CRIBS/BEDSOR PLAY PENS.THIS BAG IS NOT ATOY.
सामग्री:
Octinoxate 2.7%
निर्माता भाग संख्या:
CW382518
मॉडल नंबर:
CW361538
क्रम संख्या:
CW095040
बैच संख्या:
CW330461