विवरण
Description
-Input power supply: single-phase 220V
-Rated power: 7.5 KW
-Rated current: 30 A
-Applicable motor: 7.5KW 10HP
-Dimensions: 152 wide * 220 high * 179 thick
-Installation size: 138 wide * 205 high (mm)
-Product weight: 3.6 KG
-Scope of application: Universal type
1. * * Function**
-* * Maximum frequency * *: Vector control: 0~650 Hz, V/F control: 0~650 Hz
-Carrier frequency: 0.5 kHz~16 kHz, can automatically adjust the carrier frequency according to the load characteristics
-* * Input frequency resolution * *: Digital setting: 0.01 Hz, analog setting: maximum frequency x 0.025%
-Control Methods: Open Loop Vector Control (SVC), Closed Loop Vector Control (FVC), V/F Control
-* * Starting torque * *: G-type machine: 0.5 Hz/150% (SVC), 0 Hz/180% (FVC); P-type machine: 0.5 Hz/100%
-Speed range: 1:100 (SVC), 1:1000 (FVC)
-Stable speed accuracy: 0.5% (SVC), 0.02% (FVC)
-Torque control accuracy: 5% (FVC)
-Overload capacity: G-type machine: 150% rated current for 60 seconds; 180% rated current for 3 seconds; P-type machine: 120% rated current for 60 seconds; 150% rated current for 3 seconds
-* * Torque Boosting * *: Automatic Torque Boosting; Manual torque increased by 0.1% to 30.0%
-* * V/F curve * *: Three ways: straight line type; Multi segment type; Nth power V/F curve (1.2th power, 1.4th power, 1.6th power, 1.8th power, 2nd power)
-* * V/F separation * *: 2 methods: full separation, semi separation
-Acceleration and deceleration curve: Linear or S-shaped acceleration and deceleration method
-DC braking: DC braking frequency: 0.00 Hz~maximum frequency; Braking time: 0.0s~36.0s; Braking action current value: 0.0%~100.0%
-* * Jogging control * *: Jogging frequency range: 0.00 Hz~50.00 Hz; Jogging acceleration and deceleration time: 0.0s~6500.0s
-* * Simple PLC, multi-stage operation * *: Up to 16 stages of operation can be achieved through built-in PLC or control terminals
-* * Built in PID * *: Can facilitate the implementation of process control closed-loop control system
-Automatic Voltage Regulation (AVR): It can automatically maintain a constant output voltage when the grid voltage changes
-Overvoltage and overcurrent stall control: Automatically limits current and voltage during operation to prevent frequent overcurrent and overvoltage tripping
-* * Quick current limiting function * *: Minimizes overcurrent faults and protects the normal operation of the frequency converter
-Torque Limitation and Control: The "excavator" feature automatically limits the torque during operation to prevent frequent overcurrent tripping; Closed loop vector mode can achieve torque control
-Using high-performance current vector control technology to achieve control of asynchronous and synchronous motors**
-* * Instant stop without stop * *: During an instant power outage, compensating for the decrease in voltage through load feedback energy, the frequency converter can continue to operate for a short period of time
-* * Fast current limiting * *: Avoid frequent overcurrent faults in the frequency converter
-Virtual IO: Five sets of virtual X/DO, which can achieve simple logic control.
**Timed control * *:
-Timer control function: Set time range from 0.0Min to 6500.0Min
**Multi motor switching * *:
-Four sets of motor parameters can achieve switching control of four motors
**Multi threaded bus support * *:
-Supports four types of fieldbus: Modbus Profibus-DPCANlinkCANopen
**Motor overheat protection * *:
-Optional IO expansion card, analog input AI3 can be connected to motor temperature sensor input (PT100/PT1000)
**Multi encoder support * *:
-Supports encoders such as differential, open circuit collector, UVW, rotary transformer, sine and cosine encoders
**User programmable * *:
-Optional user programmable card for secondary development, compatible with Huichuan's PLC programming method
**Powerful backend software * *:
-Support frequency converter parameter operation and virtual oscilloscope function
-Real time graphical monitoring of the internal status of the frequency converter can be achieved through a virtual oscilloscope
2. * * Running**
-Command source: Given by operation panel, control terminal, and serial communication port. It can be switched in multiple ways.
-* * Frequency Source * *: 10 types of frequency sources, including digital settings, analog voltage settings, analog current settings, pulse settings, and serial port settings. It can be switched in multiple ways.
-* * Auxiliary frequency source * *: 10 types of auxiliary frequency sources that can flexibly achieve auxiliary frequency fine-tuning and frequency synthesis.
-* * Input terminals * *: Standard: 6 digital input terminals, 2 of which support high-speed pulse input up to 100kHz; Two analog input terminals, one only supports 0-10V voltage input, and the other supports 0-10V voltage
-
Fruugo ID:
323008578-716009908
-
EAN:
9463280231068
उत्पाद सुरक्षा जानकारी
कृपया नीचे दी गई इस उत्पाद से संबंधित विशिष्ट उत्पाद सुरक्षा जानकारी देखें
निम्नलिखित जानकारी इस उत्पाद को बेचने वाले स्वतंत्र तृतीय-पक्ष खुदरा विक्रेता द्वारा प्रदान की गई है।
उत्पाद सुरक्षा लेबल
सुरक्षा चेतावनियाँ:
Not suitable for children under 36 months