1470MHz Signal Generator FM Receiving Transmitting Comprehensive Tester Frequency Power Measurement 812VDC
Feature:
1. Wide Frequency Range: This signal generator covers a wide frequency range of 1MHz to 470MHz, allowing you to generate signals suitable for various applications. Suitable for sound modulation, transceiver signal processing, and other projects.
2. Relay Station Testing: Specifically developed for debugging and measuring U/V relay stations and FM receivers. This signal generator can operate in duplex mode, the tested machine is in the transmitting state without affecting its running. It can be applied for measurement in the forwarding state of the transfer station.
3. Accurate and Reliable: This signal generator has simple use and high reliability. With intuitive control and clear display, making settings and use easier. With a sturdy structure and stable performance, providing consistent and accurate signal generation.
4. Multiple Functions: This FM tester supports receiving and transmitting measurements, ensuring stability and reliability. In signal source mode, more testing functions can be achieved. Suitable for aviation, wireless comm, automotive electronics, manufacturing, and other fields.
5. Convenient and Practical: The FM comprehensive tester has a simple structure, multiple button controls, which is convenient and practical. The lightweight design makes it easy to use and carry, making it convenient to use at any time.
Specification:
Item Type: FM Tester
Working Voltage: 8-12V DC
Working Current: 200mA
Transmitting Measurement:
1. Frequency Measurement: 10M-900M, Resolution 1K or 0.1K
2. Power Measurement: 0.1W-64W
3. Subaudio Measurement: 50Hz-260Hz, analog subtone and standard digital subtone
Receiving Measurement:
1. Signal Generator Frequency: 1MHz-470MHz
2. Output Level: -132dBm to -90dBm
3. Single Tone Modulation: 1KHz, 2KHz, 3KHz optional, output modulation depth: 3K
4. Subtone Output: 50Hz-260Hz analog subtone and standard digital subtone, output amplitude: 0.5K
Signal Source Mode:
First Line Left: Frequency (0.5-470M), Right: Output Power (-90-131dBm)
Second Line Left: Subaudio (50.0-280.0Hz Any Analog Subtone and 105 Digital Subtone), Right: Modulation Tone (1-3K), Lower Right Corner Display Input Power
Numeric Key: For direct input of cursor indicated item
Up and Down Key: Step adjustment of cursor indicated item value
F1 Key: Cursor Pointing Movement (long press to switch to frequency counter mode)
F2 Key: Backspace Key
F3 Key: Function key, when the cursor points to output power, subaudio, and modulation tone, it is a cyclic switching function, e.g., when the cursor points to power output, this key function is to cyclically switch the signal output.
F4 Key: Not Use
Analog Subtone Setting: Directly enter subaudio point with 4 digits, if less than 4 digits, fill in 0 in front, e.g., 88.5Hz input 0, 8, 8, 5; now if you use up and down keys to adjust, it will be adjusted in steps of 0.1Hz; if you need to adjust in 50 standard subtones, you need to enter 0, 0, 0, 0, and then use up and down keys to adjust from the first standard subtone 67Hz.
Digital Subtone Setting: Enter 3 digit digital subtone code and then press F3, e.g., 023, enter 0, 2, 3, and then press F3 to set successfully; press F2 key to switch between I and N in digital subtone, adjust up and down keys in 105 sets of digital subton
Modulating tone and subtone values Input 0 is equivalent to off.
Step frequency setting: When the cursor points to the frequency, long press F3 to save the current displayed frequency as step frequency.
Frequency meter mode:
First Line: Left: frequency, right: Measurement mode AUTO/ MANUA (In order to simultaneously measure the transmissing subtone of the intercom or repeater, please select AUTO mode)
second line: left: subaudio, right: frequency resolution (1K/0.1K) (in order to test the frequency of the transmissing frequency of the intercom or repeater can choose 0.1k will be more accurate), the input power is displayed in the lower right corner
Digit Key: Not Use
Up or Down: Not Use
F1 Key: Press and hold to switch to signal source mode
F2 Key: Not Use
F3 Key: Frequency meter resolution switch 1K/0.1K
F4 Key: When the measurement mode is switched between AUTO or MANUA, at AUTO, the stable frequency is detected and automatically locked, the subtone is detected and the result is displayed until the signal disappears. After the signal disappears, the detection continues to wait for the new stable frequency. (You can detect the standard and non standard analog subtones emitted by the radio by yourself. If the radio emits digital subtones, only standard digital subtones can be
-
Fruugo ID:
347128585-758601702
-
EAN:
7851129798971
उत्पाद सुरक्षा जानकारी
कृपया नीचे दी गई इस उत्पाद से संबंधित विशिष्ट उत्पाद सुरक्षा जानकारी देखें
निम्नलिखित जानकारी इस उत्पाद को बेचने वाले स्वतंत्र तृतीय-पक्ष खुदरा विक्रेता द्वारा प्रदान की गई है।
उत्पाद सुरक्षा लेबल
सुरक्षा चेतावनियाँ:
WARNING! TO AVOID DANGER OF SUFFOCATION,KEEP AWAY FROM BABIES ANDCHILDREN. DO NOT USE IN CRIBS/BEDSOR PLAY PENS.THIS BAG IS NOT ATOY.
सामग्री:
Octinoxate 7.1510%
निर्माता भाग संख्या:
XX002171
मॉडल नंबर:
XX112490
क्रम संख्या:
PE322290
बैच संख्या:
XX858498